POSITAL Measuring Tools & Sensors CANopen, 1 Axis - 360°, Static / Accelerometer, ATEX - Zone 1 & 21 (Mining), IP65 / IP67, Stainless Steel V4A (1.4404, 316 L), 0.10°, 0.01°, Cable - 1 m Available 0General Specifications | |
Application | 1-Axis Position Monitoring and Leveling |
Measurement Range | max. 360° |
Absolute Accuracy | ±0.10° |
Resolution | 0.01° |
Electrical Specifications | |
Supply Voltage | 10 – 30 VDC |
Current Consumption | ≤ 65 mA @ 10 V DC, ≤ 60 mA @ 24 V DC |
EMC: Emitted Interference | DIN EN 61000-6-4 |
EMC: Noise Immunity | DIN EN 61000-6-2 |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
MTTF | 350 years @ 40 °C |
Environmental Specifications | |
Operating Temperature | -40 °C (-40 °F) - +80 °C (+176 °F) |
Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) |
Temperature Gradient | 0.004°/ K |
Protection Class | IP65/IP67 |
Shock Resistance | ≤ 100 g (half sine 6 ms, EN 60068-2-27) |
Vibration Resistance | 1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz) |
Mechanical Specifications | |
Housing Material | Stainless Steel V4A (1.4404, 316 L) |
Potting Material | PUR (Polyurethane) |
Weight | 200 g (0.44 lb) |
Interface | |
Interface | CANopen |
Settling Time | 150 ms |
Output Driver | Transceiver (ISO 11898), Galvanically Isolated by Opto-Coupl |
Profile | DS-410 |
Transmission Rate | min. 20 kBaud, max. 1 MBaud |
Default Transmission Rate | 125 kBaud |
Default Node ID | 1h |
Electrical Connection | |
Connection Type | Cable 1 m |
Minimum Bend Radius | 50 mm (2") fixed, 100 mm (4") flexing |
Product Life Cycle | |
Product Life Cycle | New |
Certification | |
Approval | CE + ATEX Zone 1 & 21 (Mining) |
Connection Plan | |
SIGNAL | CABLE COLOR |
Power Supply | Red |
GND | Yellow |
CAN High | White |
CAN Low | Brown |
CAN GND | Green |
Not Connected | Blue |
Not Connected | Gray |
Not Connected | Pink |
Shielding | Shield |