| Application | 1-Axis Position Monitoring and Leveling |
| Measurement Range | 360° |
| Accuracy (INL) | ±0.10° |
| Resolution | 0.01° |
| Supply Voltage | 9 – 30 VDC |
| Current Consumption | ≤ 100 mA @5V, ≤ 45 mA @10V, ≤ 25 mA @24V |
| EMC: Emitted Interference | DIN EN 61000-6-4 |
| EMC: Noise Immunity | DIN EN 61000-6-2 |
| Reverse Polarity Protection | Yes |
| Short Circuit Protection | Yes |
| MTTF | 450 years @ 40 °C |
| Min Temperature | -40 °C (-40 °F) |
| Max Temperature | +85 °C (+185 °F) |
| Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) |
| Temperature Gradient | 0.004°/ K |
| Temperature Gradient | 0.004°/ K |
| Protection Class (Housing) | IP68/IP69K |
| Shock Resistance | ≤ 100 g (half sine 6 ms, EN 60068-2-27) |
| Vibration Resistance | 1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz) |
| Housing Material | Die-Cast Aluminum Alloy |
| Potting Material | PUR (Polyurethane) |
| Weight | 220 g (0.49 lb) |
| Interface | Modbus RTU |
| Settling Time | 320 ms |
| Output Driver | Line Driver RS485 |
| Default Node ID | 127d |
| Parity | 19200 |
| Baud Rate | 2400 to 115200 |
| Connection Type | Connector M12 (5 pin) |
| Connector | M12, Male, 5 pin, a coded |
| Product Life Cycle | Discontinued |
| Approval | CE + cULus |

| Signal | Pin Number |
|---|---|
| Power Supply | 2 |
| GND | 3 |
| RS485 A | 4 |
| RS485 B | 5 |
| Signal GND | 1 |