POSITAL

ACS-120-1-AC00-VK3-PQ

ACS-120-1-AC00-VK3-PQ

General Specifications

Application1-Axis Position Monitoring and Leveling
Measurement Range120°
Accuracy (INL)±0.10°
Resolution0.01°
Cycle Time Base Sensor500 µs
Device OrientationVertical

Electrical Specifications

Supply Voltage10 – 30 VDC
Power Consumption≤ 0.7 W
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
MTTF400 years @ 40 °C

Environmental Specifications

Storage Temperature-40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient0.004°/ K
Storage Temperature-40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient0.004°/ K
Protection Class (Housing)IP68/IP69K
Shock Resistance≤ 100 g (half sine 6 ms, EN 60068-2-27)
Vibration Resistance1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz)
Min Temperature-40 °C (-40 °F)
Max Temperature+85 °C (+185 °F)

Mechanical Specifications

Housing MaterialZinc
Potting MaterialNone
Weight275 g (0.61 lb)

Interface

InterfaceAnalog#Current 4 – 20 mA
Teach InPreset
Settling Timemin 30 ms; default 200 ms (dependent on filter settings)
Output TypeCurrent 4 – 20 mA
Max Load Resistance270 Ω @ 10 V DC (500 Ω @ 15 V DC)
Linearity± 0.02%

Electrical Connection

Connection TypeConnector M12 (8 pin)
ConnectorM12, Male, 8 pin, a coded

Product Life Cycle

Product Life CycleNew

Certification

ApprovalCE

Connection Plan

SignalPin Number
Power Supply1
GND4
Z-Axis, Current Output5
Set16
Do Not Connect8
Do Not Connect2
Do Not Connect3
Do Not Connect7

Dimensional Drawing

Dimensional Drawing
Analog Output Characteristics
Analog Output Characteristics

Downloads