IXARC Absolute Rotary Encoder

UCD-AV1P1-PPPP-L100-PRM

POSITAL Measuring Tools & Sensors Analog Programmable - Voltage 0-5V Preset +Dir, Multiturn - Programmable, Programmable, IP64 / IP65, Aluminum / Steel, Solid Shaft - Clamping, ø 58 mm (2.28"), ø 10 mm (0.39"), Connector - Radial M12, ≤ 0.09° (Magnetic - Hall Effect), CE / UL Available 0
picture-cx-5-crx-mx-nnn.jpg
Interface
InterfaceProgrammable Analog Voltage (Preset + Dir)
Manual FunctionsPreset + complement via cable or connector
Configuration ToolUBIFAST Configuration Tool (Version ≥ 1.6.10) + Ubifast Adap
Video Manualvideo-link Watch a simple installation video
Programming FunctionsMeasurement Range, Preset Value, Output Direction, Code
Electrical Data
Supply Voltage8 – 32 VDC
Current ConsumptionTypical 15 mA @24V (no load)
Start-Up Time<500 ms
Min. Load Resistance5 kΩ
Analog Accuracy@ 10 V = ±10 mV (with an ideal power supply)
Linearity0.15%
Settling Time32 ms (from min value to max value jump)
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
MTTF240.8 years @ 40 °C
Sensor
TechnologyMagnetic
Multiturn TechnologySelf powered magnetic pulse counter (no battery, no gear)
Accuracy (INL)±0.0878° (≤ 12 bit)
CodeProgrammable Analog Voltage 0-5 V or 0.5-4.5 V, preprogrammed 0-5V
Cycle Time Base Sensor< 100 µs
Minimum Measurement Range0 – 11.25°
Resolution of OutputMax. 13 bits over entire measuring range (Fractional Turns - Resolution decreases less than 13 bits when measuring range is less than 90 degrees)
Multiturn Range16 turn (default setting). User can use the UBIFAST Tool to measure up to 65536 turns.
Environmental Specifications
Protection Class (Shaft)IP65
Protection Class (Housing)IP66/IP67
Operating Temperature-40 °C (-40 °F) - +85 °C (+185 °F)
Humidity98% RH, no condensation
Mechanical Data
Housing MaterialSteel
Housing CoatingWet coating (RAL 9006 White Aluminium) + Cathodic corrosion protection (>720 h salt spay resistance)
Flange TypeClamp, ø 58 mm (L)
Flange MaterialAluminum
Shaft TypeSolid, Single Flat, Length = 20 mm
Shaft Diameterø 10 mm (0.39")
Shaft MaterialStainless Steel V2A (1.4305, 303)
Max. Shaft LoadAxial 40 N, Radial 110 N
Minimum Mechanical Lifetime
(10^8 revolutions with Fa/Fr)
430 (20 N / 40 N), 150 (40 N / 60 N), 100 (40 N / 80 N), 55 (40 N / 110 N)
Rotor Inertia≤ 30 gcm² [≤ 0.17 oz-in²]
Friction Torque≤ 3 Ncm @ 20 °C (4.2 oz-in @ 68 °F)
Max. Permissible Mechanical Speed≤ 12000 1/min
Shock Resistance≤ 100 g (half sine 6 ms, EN 60068-2-27)
Permanent Shock Resistance≤ 10 g (half sine 16 ms, EN 60068-2-29)
Vibration Resistance≤ 10 g (10 Hz – 1000 Hz, EN 60068-2-6)
Length52,7 mm (2.07")
Weight325 g (0.72 lb)
Electrical Connection
Connection OrientationRadial
ConnectorM12, Male, 5 pin, a coded
Certification
ApprovalCE + cULus
Product Life Cycle
Product Life CycleNew
Connection Plan
SIGNALCONNECTORPIN NUMBER
Power SupplyConnector 12
GNDConnector 13
Analog OutputConnector 11
Set1/DirectionConnector 15
Set2/Zero SetConnector 14
Connector-View on Encoder
Dimensional Drawing

If the drawings are not available please refer to the "Download" section.

The picture and drawing are for general presentation purposes only. All dimension in [inch] mm.

© FRABA B.V., All rights reserved. We do not assume responsibility for technical inaccuracies or omissions. Specifications are subject to change without notice.