LINARIX Linear Sensor
LU0-S101B-1216-3D0A-ARW
POSITAL
Measuring Tools & Sensors
IP64 / IP65, Draw Wire - 3 m – 6.9 m (9.84' – 22.63'), SSI / SSI + Incremental - Binary, 16 bit (65536 Steps), Draw Wire Enclosure - Machined Metal - Rectangular Housing, Cable - Radial 10 m, Radial 0 / Axial, Magnetic (≤ 0.09°)
Available
0
This is an exiting product! It will be discontinued soon.
General Data Supply Voltage 4.5 – 30 VDC Power Consumption ≤ 1.0 W Turn On Time < 1 s Operating Temperature -30 °C fixed (-22 °F), -5 °C flexible (+23 °F) - +80 °C (+176 °F) Weight 965 g (2.13 lb) Protection Class (Encoder) IP64 / IP65 EMC: Emitted Interference DIN EN 61000-6-4 EMC: Noise Immunity DIN EN 61000-6-2
Mechanical Data Max. Measurement Length 3.00 m (9.84') Length per Revolution 200 mm Wire Material Plastic Coated Stainless Steel Wire Diameter 0.61 mm Encoder Housing Material Steel Draw Wire Housing Material Zinc Die-cast Max. Speed of Wire Displacement 0.8 m / s Max. Wire Acceleration 1.0 g Max. Extension Force 3.0 N Min. Retraction Force 2.5 N Actuation Lifetime Not Available Wire Mounting M6 Thread Max. Wire Exit Angle ±0°
Sensor Data Technology Magnetic (≤ 0.09°) Accuracy ±0.012 % FSO Repeatability ±0.005 % FSO Resolution [Encoder - Singleturn] 16 bit Resolution [Encoder - Multiturn] 12 bit Approx. Linear Resolution 3.1 µm (theoretical), limited by mechanics Output Code Binary
Interface Communication Interface SSI with Preset Manual Functions Preset + complement via cable or connector Cycle Time Interface ≥ 25 µs
Outputs Output Driver RS422 Current Consumption Typical 50 mA Clock Input RS 422, via Optocoupler Clock frequency 100 kHz – 2 MHz Reverse Polarity Protection Yes Short Circuit Protection Yes MTTF 350 years @ 40 °C
Electrical Connection Connection Orientation Radial Connection Orientation (w.r.t Draw Wire) Radial 0 / Axial Cable Length 10 m [394"] Wire Cross Section 0.14 mm² / AWG 26 Material / Type PVC Cable Diameter 6 mm (0.24 in) Minimum Bend Radius 46 mm (1.81") fixed, 61 mm (2.4") flexing
Product Life Cycle Product Life Cycle Exiting
Connection Plan SIGNAL CABLE COLOR Power Supply Brown GND White Data+ Gray Data- Pink Clock+ Green Clock- Yellow Preset Blue DIR Red Shielding Shield
All dimension in [inch] mm. Encoder dimensions may vary depending on electrical interface and connector. This drawing and the information contained is for general presentation purposes only. Please refer to the "Download" section for detailed technical drawings.