Application | 2-Axes Position Monitoring and Leveling |
Measurement Range | ± 5° |
Accuracy (INL) | ±0.01° |
Resolution | 0.001° |
Supply Voltage | 10 – 30 VDC |
Current Consumption | ≤ 100 mA @5V, ≤ 45 mA @10V, ≤ 25 mA @24V |
EMC: Emitted Interference | DIN EN 61000-6-4 |
EMC: Noise Immunity | DIN EN 61000-6-2 |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
MTTF | 300 years |
Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) |
Temperature Gradient | 0.001°/ K |
Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) |
Temperature Gradient | 0.001°/ K |
Protection Class (Housing) | IP66/IP67 |
Shock Resistance | ≤ 300 g (half sine 6 ms, EN 60068-2-27) |
Vibration Resistance | 10 – 150 Hz, 2.5 mm amplitude, 5 g const. Acceleration |
Min Temperature | -30 °C fixed (-22 °F), -5 °C flexible (+23 °F) |
Max Temperature | +80 °C (+176 °F) |
Housing Material | Aluminum |
Weight | 510 g (1.12 lb) |
Interface | RS232 |
Transmission Rate | RS232: min. 2400 Baud; max. 57600 Baud |
Default Transmission Rate | RS232: 9600 Baud |
Connection Type | Cable 2 m PVC |
Connector | Cable 2 m |
Cable Length | 2 m [79"] |
Wire Cross Section | 0.14 mm² / AWG 26 |
Material / Type | PVC |
Cable Diameter | 6 mm (0.24 in) |
Minimum Bend Radius | 40 mm (1.57") fixed, 80 (3.15") flexing |
Product Life Cycle | Discontinued |