POSITAL

ACS-120-1-SV00-VE2-PM

ACS-120-1-SV00-VE2-PM
This product is discontinued
This product is replaced by
ACS-120-1-AV00-VE3-PQ

General Specifications

Application1-Axis Position Monitoring and Leveling
Measurement Range120°
Accuracy (INL)±0.10°
Resolution0.01°
Device OrientationVertical

Electrical Specifications

Supply Voltage10 – 30 VDC
Power Consumption≤ 0.7 W
EMC: Emitted InterferenceDIN EN 61000-6-4
EMC: Noise ImmunityDIN EN 61000-6-2
Reverse Polarity ProtectionYes
Short Circuit ProtectionYes
MTTF400 years @ 40 °C

Environmental Specifications

Storage Temperature-40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient0.004°/ K
Storage Temperature-40 °C (-40 °F) – +85 °C (+185 °F)
Temperature Gradient0.004°/ K
Protection Class (Housing)IP66/IP67
Shock Resistance≤ 100 g (half sine 6 ms, EN 60068-2-27)
Vibration Resistance1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz)
Min Temperature-40 °C (-40 °F)
Max Temperature+85 °C (+185 °F)

Mechanical Specifications

Housing MaterialFibre-Reinforced PBT (Polybutylene Terephthalate)
Potting MaterialPUR (Polyurethane)
Weight100 g (0.22 lb)

Interface

InterfaceAnalog#Voltage 0.5-4.5 V + RS232
Teach InZero Positioning, Inverse Direction, Elevation Range Programming
Settling Time125 ms
Output TypeVoltage 0.5 – 4.5 V
Min. Load Resistance5 kΩ
Transmission RateRS232: min. 1200 Baud; max. 115200 Baud
Default Transmission RateRS232: 9600 Baud
Linearity± 0.02%

Electrical Connection

Connection TypeConnector M12 (8 pin)
ConnectorM12, Male, 8 pin, a coded

Product Life Cycle

Product Life CycleDiscontinued

Certification

ApprovalCE + cULus

Connection Plan

Connection plan
SignalPin Number
Power Supply1
GND4
Z-Axis, Voltage Output5
Set16
Set28
RxD2
TxD3
Not Connected7

Dimensional Drawing

Dimensional Drawing
Analog Output Characteristics
Analog Output Characteristics

Downloads