| Application | 2-Axes Position Monitoring and Leveling | 
| Measurement Range | ± 10° | 
| Accuracy (INL) | ±0.10° | 
| Resolution | 0.01° | 
| Device Orientation | Horizontal | 
| Supply Voltage | 10 – 30 VDC | 
| Power Consumption | ≤ 0.7 W | 
| EMC: Emitted Interference | DIN EN 61000-6-4 | 
| EMC: Noise Immunity | DIN EN 61000-6-2 | 
| Reverse Polarity Protection | Yes | 
| Short Circuit Protection | Yes | 
| MTTF | 400 years @ 40 °C | 
| Min Temperature | -40 °C (-40 °F) | 
| Max Temperature | +80 °C (+176 °F) | 
| Storage Temperature | -40 °C (-40 °F) – +85 °C (+185 °F) | 
| Temperature Gradient | 0.004°/ K | 
| Temperature Gradient | 0.004°/ K | 
| Protection Class (Housing) | IP68/IP69K | 
| Shock Resistance | ≤ 100 g (half sine 6 ms, EN 60068-2-27) | 
| Vibration Resistance | 1.5 mm (10 Hz – 58 Hz) & ≤ 20 g (58 Hz to 2000 Hz) | 
| Housing Material | Die-Cast Aluminum Alloy | 
| Potting Material | PUR (Polyurethane) | 
| Weight | 970 g (2.14 lb) | 
| Interface | Analog#Voltage 0-5 V + RS232 | 
| Teach In | Zero Positioning, Inverse Direction, Elevation Range Programming | 
| Settling Time | 125 ms | 
| Output Type | Voltage 0 – 5 V | 
| Min. Load Resistance | 5 kΩ | 
| Transmission Rate | RS232: min. 1200 Baud; max. 115200 Baud | 
| Default Transmission Rate | RS232: 9600 Baud | 
| Linearity | ± 0.02% | 
| Connection Type | Cable 5 m PVC | 
| Cable Length | 5 m [197"] | 
| Wire Cross Section | 0.34 mm² / AWG 22 | 
| Material / Type | PUR / PU | 
| Cable Diameter | 7.5 mm (0.30 in) | 
| Minimum Bend Radius | 56 mm (2.2") fixed, 75 mm (3") flexing | 
| Product Life Cycle | Discontinued | 
| Signal | Color | 
|---|---|
| Power Supply | Red | 
| GND | Yellow | 
| X-Axis, Voltage Output | Green | 
| Y-Axis, Voltage Output | Blue | 
| RxD | Gray | 
| TxD | Pink | 
| Set1 | Brown | 
| Set2 | White | 
| Shielding | Shield | 