| Safety Certificate | 4479913172909 |
| Safety Integrity Level | SIL CL 2 |
| Safety Performance Level | PL d |
| Safety Category | Cat 2 |
| MTTFd (EN ISO 13849-1) | 162 years |
| Intended Time of Usage (EN 61508 and EN 62061) | 20 years |
| HFT (EN 61508 and EN 62061) | 0 |
| SFF (EN 61508 and EN 62061) | 92.2% |
| PFHd (EN 61508 and EN 62061) | 9.889*10-8 1/h |
| Safety Input Data (point of view PLC) | 2 byte status4 byte position data2 byte speed data |
| Tolerance of the internal position monitoring | 1.5% (with reference to one revolution) |
| Internal updating time of the position value | 1 ms |
| Internal updating time of the velocity value | 1 ms |
| DCavg (EN ISO 13849-1) | 86.1% |
| Online Data Sheet Version | Version 1, Date 20160115 |
| Certified Data Sheet Version | See download section for the certified data sheet. Version 1, 20160114 |
| Certified Organization | FRABA B.V. , Jan Campertstraat 11, NL-6416 SG Heerlen |
| Company Address | FRABA GmbH, Zeppelinstraße 2, 50667 Cologne, Germany |